Research /

Research group

X-Ray Wave Imaging for Health

Better see, better understand pathologies and their treatments in 3D.

AttenuationRefraction · phasedotted: reference, without sampleScattering · dark-field
An X-ray wave crossing a sample: its amplitude drops (attenuation), its phase shifts (refraction) and it spreads (scattering).

Conventional X-ray imaging only measures how much a sample absorbs. X rays are also waves: they are refracted and scattered, and these signals reveal what absorption cannot see. This is what we exploit.

Three signals, three sensitivities

SignalWhat it senses
AbsorptionHard tissue
Refraction (phase contrast)Soft tissue
Scattering (dark-field)Structures much smaller than the pixel, down to about one hundredth of its size

Together they give multiscale 3D images of complete, unlabelled biological samples, from the whole organ down to a single cell and its environment.

Applications across scales

  • Virtual histology, a 3D, non-destructive alternative to slicing and staining, for brain (including Alzheimer’s disease), osteoarticular tissue, liver and human embryonic and fetal organs.
  • Joint disease. In mouse models of osteoarthritis, phase-contrast micro-CT shows cartilage and bone structure that MRI and conventional micro-CT miss. At clinically compatible scale, we studied the benefit of the technique for diagnosing osteoarthritis on human wrists, using synchrotron X rays at high energy.
  • Lung function. With 4D synchrotron micro-tomography we map lung tissue deformation in vivo with microscopic resolution, and made the first observation of terminal bronchi closing during mechanical ventilation.
  • Contrast agents. Spectral and dark-field imaging to track nanoparticle-labelled cells with small amounts of high-atomic-number or lower-atomic-number elements.

From the synchrotron to the clinic

The synchrotron remains the gold standard. Our goal is to bring its image quality to conventional sources, then to patients.

  1. Synchrotron. Where the methods are first demonstrated.
  2. Laboratory. The MUSITOX platform , the world’s first wave-based imaging platform using conventional X-ray sources. We simplified dark-field imaging down to a single, easy-to-make membrane that modulates the beam, with random or designed patterns.
  3. Clinic. Phase-contrast and dark-field CT for oral healthcare, developed in the ANR ROOTS project and by the spin-off project arXimed, supported by the SATT Linksium.

Oral healthcare

Compared with conventional cone-beam CT, phase-contrast CT of a jaw specimen shows teeth, gingiva, neurovascular bundles and even skin layers that conventional CT blurs. The arXimed project won the Grand Prix of the i-PhD innovation contest.

What comes next

  • Molecular contrast agents that produce X-ray scattering, to image vascularisation.
  • Skin characterisation.
  • Detection of boron in depth, in support of neutron capture therapy.